Numerical calculation on iron and pulsation losses on induction machines with open stator slots

Germishuizen J. J. ; Jockel, A. ; Kamper M. J. (2007)

Conference Paper

Pulsation losses, which are very difficult to measure, are present in every squirrel cage induction motor and depend mainly on the geometrical design. This paper primarily deals with the question whether these losses can be calculated by means of numerical methods. For this purpose two induction motors that only differ in the slot design are measured at no- and full-load and compared with the computed results.

Please refer to this item in SUNScholar by using the following persistent URL: http://hdl.handle.net/10019.1/43490