Browsing by Author "Schoenfeld, P. D."
Now showing 1 - 1 of 1
Results Per Page
Sort Options
- ItemFlooding during reflux condensation of steam in an inclined elliptical tube(South African Institution of Mechanical Engineering, 2000) Schoenfeld, P. D.; Kroger, D. G.In this erperimental inuestigation the pressure drop is measured between the headers located at the ends of an in,clined air-cooled elliptical tube in which refl,ur condensation of steam occurs. The cross-section of the 7 m long tube has a height of g7 mm (major aris) and a width of 16 mm (minor ads). Steam temperatures are in the range of 45o C to 65o C. The pressure drop can be predicted accurately using the Z apke- I(rri g er pressure drop model applicable to refl,ur condensers. At a certain steam fl,ou, rate a sudden sharp increase in the pressure drop occurs. This phenoTne?t,on is lcnowrt, &s fl,ooding. The rneasured aapour uelocities at fl,oodin,g agree well with the ualues predicted by the Zapke-Krciger fl,ooding correlation. The erperimental results also show that flooding has a detrimental effect on the thermal effectiueness of Ihe elliptical tube.