A T-resonator technique to measure admittance parameters of electrically short monopoles at radio frequencies

Date
2004
Authors
Kwinana P.M.
Cloete J.H.
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
An experimental technique to accurately determine admittance parameters of electrically short monopoles is presented. Measurements were taken using an HP 8510C network analyser in the frequency range 45 MHz to 3 GHz. The experimental results compare well with numerical predictions. Both bare and insulated monopoles were studied.