The accuracy of radiology speech recognition reports in a multilingual South African teaching hospital

dc.contributor.authorDu Toit, Jacquelineen_ZA
dc.contributor.authorHattingh, Rethaen_ZA
dc.contributor.authorPitcher, Richarden_ZA
dc.date.accessioned2016-11-01T06:20:54Z
dc.date.available2016-11-01T06:20:54Z
dc.date.issued2015-03en_ZA
dc.descriptionCITATION: Du Toit, J., Hattingh, R. & Pitcher, R. 2015. The accuracy of radiology speech recognition reports in a multilingual South African teaching hospital. BMC Medical Imaging, 15:8, doi:10.1186/s12880-015-0048-1.en_ZA
dc.descriptionThe original publication is available at http://bmcmedimaging.biomedcentral.com
dc.description.abstractBackground: Speech recognition (SR) technology, the process whereby spoken words are converted to digital text, has been used in radiology reporting since 1981. It was initially anticipated that SR would dominate radiology reporting, with claims of up to 99% accuracy, reduced turnaround times and significant cost savings. However, expectations have not yet been realised. The limited data available suggest SR reports have significantly higher levels of inaccuracy than traditional dictation transcription (DT) reports, as well as incurring greater aggregate costs. There has been little work on the clinical significance of such errors, however, and little is known of the impact of reporter seniority on the generation of errors, or the influence of system familiarity on reducing error rates. Furthermore, there have been conflicting findings on the accuracy of SR amongst users with English as first- and second-language respectively. Methods: The aim of the study was to compare the accuracy of SR and DT reports in a resource-limited setting. The first 300 SR and the first 300 DT reports generated during March 2010 were retrieved from the hospital’s PACS, and reviewed by a single observer. Text errors were identified, and then classified as either clinically significant or insignificant based on their potential impact on patient management. In addition, a follow-up analysis was conducted exactly 4 years later. Results: Of the original 300 SR reports analysed, 25.6% contained errors, with 9.6% being clinically significant. Only 9.3% of the DT reports contained errors, 2.3% having potential clinical impact. Both the overall difference in SR and DT error rates, and the difference in ‘clinically significant’ error rates (9.6% vs. 2.3%) were statistically significant. In the follow-up study, the overall SR error rate was strikingly similar at 24.3%, 6% being clinically significant. Radiologists with second-language English were more likely to generate reports containing errors, but level of seniority had no bearing. Conclusion: SR technology consistently increased inaccuracies in Tygerberg Hospital (TBH) radiology reports, thereby potentially compromising patient care. Awareness of increased error rates in SR reports, particularly amongst those transcribing in a second-language, is important for effective implementation of SR in a multilingual healthcare environment.en_ZA
dc.description.urihttp://bmcmedimaging.biomedcentral.com/articles/10.1186/s12880-015-0048-1
dc.description.versionPublisher's version
dc.format.extent5 pagesen_ZA
dc.identifier.citationDu Toit, J., Hattingh, R. & Pitcher, R. 2015. The accuracy of radiology speech recognition reports in a multilingual South African teaching hospital. BMC Medical Imaging, 15:8, doi:10.1186/s12880-015-0048-1.en_ZA
dc.identifier.issn1471-2342 (online)
dc.identifier.otherdoi:10.1186/s12880-015-0048-1
dc.identifier.urihttp://hdl.handle.net/10019.1/99784
dc.language.isoen_ZAen_ZA
dc.publisherBioMed Central
dc.rights.holderAuthors retain copyright
dc.subjectSpeech perceptionen_ZA
dc.subjectMedical errors -- Reportingen_ZA
dc.subjectRadiology -- South Africaen_ZA
dc.subjectCommunicationen_ZA
dc.titleThe accuracy of radiology speech recognition reports in a multilingual South African teaching hospitalen_ZA
dc.typeArticleen_ZA
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
dutoit_accuracy_2015.pdf
Size:
330.78 KB
Format:
Adobe Portable Document Format
Description:
Download article
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.95 KB
Format:
Item-specific license agreed upon to submission
Description: