Impact of pulsed xenon ultraviolet disinfection on surface contamination in a hospital facility’s expressed human milk feed preparation area

dc.contributor.authorDippenaar, Rickyen_ZA
dc.contributor.authorSmith, Johanen_ZA
dc.date.accessioned2018-02-26T05:31:37Z
dc.date.available2018-02-26T05:31:37Z
dc.date.issued2018-02-23
dc.date.updated2018-02-25T04:17:09Z
dc.descriptionCITATION: Dippenaar, R. & Smith, J. 2018. Impact of pulsed xenon ultraviolet disinfection on surface contamination in a hospital facility’s expressed human milk feed preparation area. BMC Infectious Diseases, 18:91, doi:10.1186/s12879-018-2997-9.
dc.descriptionThe original publication is available at https://bmcinfectdis.biomedcentral.com
dc.description.abstractBackground; Expressed human milk (EHM) feed preparation areas represent a potential source of unintentional nosocomial infection. Daily disinfection of environmental surfaces remains an essential intervention to mitigate nosocomial infections. The inefficiency of conventional cleaning and disinfection contributes to an increased risk for the acquisition of multi-drug resistant pathogens. “Non touch” technologies such as the pulsed xenon ultraviolet (PX-UVD) light device have documented sustained reduction in surface bacterial colonization and reduced cross contamination. Methods: The impact of a PX-UVD on surface colony forming units per square centimeter (cfu/cm2) in feed preparation areas was evaluated following its implementation as standard care. A quasi-experimental study was performed documenting bacterial colonization from 6 high risk feed preparation areas in a community care hospital in South Africa. Pre and post conventional cleaning neutralizing rinse swabs were collected fortnightly over a 16 week control period prior to the introduction of the PX-UVD and compared to a matching set of samples for the PX-UVD period. Results: A 90% reduction in total surface bioburden was noted from the control period (544 cfu/cm2) compared to the corresponding PX-UVD period (50 cfu/cm2). Sub -analysis of both the Pre-clean Control: Pre-clean PX-UVD counts as well as the Post-clean Control: Post-clean PX-UVD counts noted significant improvements (p < 0.001). A statistically significant improvement was noted between pre-and post-cleaning total surface bioburden following exposure to the PX-UVD (p = 0.0004). The introduction of the PX-UVD was associated with a sustained reduction in the pre clean bioburden counts with a risk trend (per week) 0.19, (95% CI [0.056, 0.67], p = 0.01). Discussion: The use of a PX-UVD as adjunct to standard cleaning protocols was associated with a significant decrease in surface bioburden. The study demonstrated the inefficiency of conventional cleaning. Persistence of potentially pathological species in both periods highlights current health sector challenges.
dc.description.urihttps://bmcinfectdis.biomedcentral.com/articles/10.1186/s12879-018-2997-9
dc.description.versionPublisher's version
dc.format.extent6 pagesen_ZA
dc.identifier.citationDippenaar, R. & Smith, J. 2018. Impact of pulsed xenon ultraviolet disinfection on surface contamination in a hospital facility’s expressed human milk feed preparation area. BMC Infectious Diseases, 18:91, doi:10.1186/s12879-018-2997-9
dc.identifier.issn1471-2334 (online)
dc.identifier.otherdoi:10.1186/s12879-018-2997-9
dc.identifier.urihttp://hdl.handle.net/10019.1/103185
dc.language.isoen_ZAen_ZA
dc.publisherBioMed Centralen_ZA
dc.rights.holderAuthor retains copyrighten_ZA
dc.subjectHospital infectionen_ZA
dc.subjectBreastfeeding -- Popular worksen_ZA
dc.subjectPulsed xenon ultravioleten_ZA
dc.subjectHealth facilities -- Disinfectionen_ZA
dc.titleImpact of pulsed xenon ultraviolet disinfection on surface contamination in a hospital facility’s expressed human milk feed preparation areaen_ZA
dc.typeArticleen_ZA
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
dippenaar_impact_2018.pdf
Size:
486.99 KB
Format:
Adobe Portable Document Format
Description:
Download article
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.95 KB
Format:
Item-specific license agreed upon to submission
Description: