Anatomy of the clavicle and its medullary canal - a computer tomography study

dc.contributor.authorKing, Paul Reginalden_ZA
dc.contributor.authorIkram, Ajmalen_ZA
dc.contributor.authorLamberts, Robert Patricken_ZA
dc.contributor.otherStellenbosch University. Faculty of Health Sciences. Dept. of Surgical Sciences: Orthopaedic Surgery.en_ZA
dc.date.accessioned2015-07-27T06:29:33Z
dc.date.available2015-07-27T06:29:33Z
dc.date.issued2014-12
dc.descriptionThesis (MMed)--Stellenbosch University, 2014en_ZA
dc.description.abstractENGLISH ABSTRACT: Background With recent literature indicating certain clavicle shaft fracture types are best treated surgically; there is renewed interest in the anatomy of the clavicle. lntramedullary fixation of clavicle shaft fractures requires an adequate medullary canal to accommodate the fixation device used. This computer tomography anatomical study of the clavicle and its medullary canal describes its general anatomy and determines the suitability of its medullary canal to intramedullary fixation. Description of methods Four hundred and eighteen clavicles in 209 patients were examined using computer tomography imaging. The length and curvatures as well as the height and width of the clavicle and its canal at various pre-determined points were measured. ln addition the start and end of the medullary canal from the sternal and acromial ends of the clavicle were determined. The data was grouped according to age, gender and lateralization. Summary of results The average length of the clavicle was 151.15 mm with the average stemal and acromial curvature being 146 and 133 respectively. The medullary canal starts on average 6.59 mm from the sternal end and ends 19.56 mm from the acromial end with the average height and width of the canal at the middle third being 5.61 mm and 6.63 mm respectively. Conclusion The medullary canal of the clavicle is large enough to accommodate commonly used intramedullary devices in the nraprity of cases. The medullary canal extends far enough medially and laterally for an intramedullary device to adequatet'y bridge most middte third clavicle fractures. An alternative surgical option should be avalable in theatre when treating females as the medullary canal is too small to pass an intranedullary device past the fracture site on rare occasions.en_ZA
dc.format.extent27 pages : illustrationsen_ZA
dc.identifier.urihttp://hdl.handle.net/10019.1/97308
dc.language.isoen_ZAen_ZA
dc.publisherStellenbosch Univeristyen_ZA
dc.rights.holderStellenbosch Universityen_ZA
dc.subjectClavicle -- Anatomyen_ZA
dc.subjectMedullary canalen_ZA
dc.subjectClavicle -- Surgeryen_ZA
dc.titleAnatomy of the clavicle and its medullary canal - a computer tomography studyen_ZA
dc.typeThesisen_ZA
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
king_anatomy_2014.pdf
Size:
11.22 MB
Format:
Adobe Portable Document Format
Description:
Download PDF
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.95 KB
Format:
Item-specific license agreed upon to submission
Description: