Department of Pathology
Permanent URI for this community
Browse
Browsing Department of Pathology by Subject "Abnormal FLC levels and FLC ratio"
Now showing 1 - 1 of 1
Results Per Page
Sort Options
- ItemFree light chains in patients with HIV: establishing local reference ranges and their association with stage of disease, chronic antigen stimulation and the effect of Haart(Stellenbosch : Stellenbosch University, 2012-03) Germishuys, Jurie J.; Zemlin, Annalise E.; Erasmus, Rajiv T.; Stellenbosch University. Faculty of Health Sciences. Dept. of Pathology. Chemical Pathology.ENGLISH ABSTRACT: Background: Serum free light chains (FLC) are associated with imbalances in heavy and light chain production. Abnormal FLC ratios have been associated with risk of progression in certain diseases. Automated assays are available for their determination and they are used in the followup and management of patients with monoclonal gammopathies. Acceptable imprecision, specificity, accuracy and reproducibility between reagent batches is required to prevent under- or overestimation. Method validation is a standard process in every good laboratory to judge the acceptability of a new method. Reference intervals have been established in an older population, but it was considered important to verify these in our population. HIV is associated with B-cell dysfunction. As B-cell abnormalities are associated with disorders leading to monoclonal gammopathies, we postulated that the FLC levels and FLC ratio would be abnormal in HIV infected individuals. Methods and materials: Controls and pooled patient samples were used for the method validation study which included imprecision studies, linearity, recovery and interference studies, and method comparison studies, the latter compared our method to the same method used in another laboratory. For the reference interval study, blood was obtained from 120 healthy subjects. The following blood tests were performed: total protein, IgG, IgA, IgM, creatinine, protein electrophoresis, kappa FLC and lambda FLC. Using the kappa and lambda FLC results, a FLC ratio was determined. Three hundred and sixty-nine HIV positive subjects were then studied. The same tests were performed, as well as CD4+ counts and viral loads on the majority of them. Results: For the method validation study, precision, linearity and recovery was acceptable. Minimal interference was observed with haemolysis, lipaemia, bilirubin and rheumatoid factor. Our method showed comparable performance with the established method. For the reference interval study, all the creatinine values were normal, as were serum protein values. The serum protein electrophoreses were independently reviewed by 3 pathologists. Most were normal, with a few polyclonal increases seen, but no definite monoclonal bands. The 95% reference intervals for FLC’s as well as the FLC ratio were not statistically significantly different to the manufacturer’s recommendations. When examining the HIV positive study population, we found that FLC and FLC ratio were influenced by markers of HIV disease severity, such as CD4+ count, IgG, viral load, use of antiretroviral treatment and abnormal serum protein electrophoreses. Conclusion: The validation study of FLC showed excellent precision, acceptable bias, good linearity, good recovery and minimal interference, allowing routine introduction of the test. The 95% reference intervals obtained for our population were slightly higher than those recommended by the manufacturer. However, as most of the values fell within the manufacturer’s limits, we could accept the manufacturer’s recommended cut-offs. We found that FLC levels were definitely influenced by markers of HIV disease severity in our population and we postulate that they may be of use for follow-up of patients with HIV.