Browsing by Author "Van der Merwe, J. J."
Now showing 1 - 1 of 1
Results Per Page
Sort Options
- ItemParameters affecting accuracy and reproducibility of sedimentary particle size analysis of clays(Stellenbosch : Stellenbosch University, 2004-04) Van der Merwe, J. J.; Allen, T.; Wickens, H. de V.; Stellenbosch University. Faculty of Science. Dept. of Earth Sciences.ENGLISH ABSTRACT: The main aim of this study is to establish a standard procedure for all sedimentary particle size analysis methods specifically for clay minerals and mixtures thereof. Not only will it improve accuracy and reproducibility during clay size analysis, it will also secure comparability between different operators. As a start, all the apparatus-related parameters that can affect the accuracy and reproducibility were determined for the apparatus used, viz. the Sedigraph SOOOD. Thereafter, these parameters were kept constant, and the effects of potential material-related parameters were investigated one-by-one. First to be investigated were those parameters relating specifically to sample preparation. They were: grinding intensity, chemical dissolution of cementing materials, duration of prior soaking, salt content, centrifugal washing with polar organic liquids, deflocculant type and concentration, the effect of pH, ultrasonic time, and stirring during ultrasonic treatment. Then, the influence on accuracy and reproducibility of the physical and chemical parameters related to the suspension was determined. They were: the use of the viscosity and density of water to calibrate the apparatus in stead of those of the suspension liquid, hydrolysis of the deflocculant with suspension-ageing, and the effect of solid concentration on hindered settling. During this investigation a novel method was developed to enable faster and more accurate pycnometric density determinations. Next, the unique characteristics of clays, which can influence the results of sedimentary particle size analyses, were examined. Serious problems are encountered with the accuracy of the analyses of some clay types abundantly found in nature, viz. the smectites and mixed-layered clay minerals. Due to their swelling in water, and variations in the amounts of their crystal layers, they experience unpredictable changes in particle size. The latter is caused by the following external factors: clay type, humidity, type of exchange cation, electrolyte concentration, clay concentration, pH, deflocculant type and concentration, pressure history of the swell-clay suspension, and ageing of the suspension. The effect of each of them on the accuracy and reproducibility of the sedimentary particle size analysis of clays are investigated in detail. Another problem that influences the accuracy of the sedimentary methods is that owing to swelling, the densities of smectites and mixed-layered clays change by varying degrees when suspended in water. It is, however, impossible to pycnometrically determine the density of a swell-clay since it absorbs a part of the water used for its volume determination. To solve this problem, a novel method was devised to calculate swell-clay density. This method makes use of existing Monte Carlo simulations of the swelling mechanism of montmorillonite. During all sedimentary methods, an average clay density is normally used to calculate the particle size distribution of clay mixtures. However, if there is a large enough difference between the calculated average density and that of a component, then inaccurate results will be recorded. The magnitude of this effect was investigated for a few self-made clay mixtures, which consisted of different proportions of kaolinite, illite, and montmorillonite. Based on all the above results, a practical approach to, and a standard methodology for all the sedimentary methods of particle size analysis of clay minerals are presented. Additionally, a condensed summary is provided in table-form, which contains the magnitudes of the errors associated with each of the parameters that were examined.