Browsing by Author "Singo, Thifhelimbilu Daphney"
Now showing 1 - 1 of 1
Results Per Page
Sort Options
- ItemDevelopment of a high flux neutron radiation detection system for in-core temperature monitoring(Stellenbosch : Stellenbosch University, 2012-03) Singo, Thifhelimbilu Daphney; Papka, Paul; Wyngaardt, Shaun M.; Dobson, Robert T.; Smit, F. D.; Stellenbosch University. Faculty of Sciences. Dept. of Physics.ENGLISH ABSTRACT: The objective of this research was to develop a neutron detection system that incorporates a mass spectrometer to measure high neutron flux in a nuclear reactor environment. This system consists of slow and fast neutron detector elements for measuring fluxes in those energy regions respectively. The detector should further be capable of withstanding the harsh conditions associated with a high temperature reactor. This novel detector which was initially intended for use in the PBMR reactor has possible applications as an in-core neutron and indirect temperature-monitoring device in any of the HTGR. Simulations of a generic HTGR core model were performed in order to obtain the neutron energy spectrum with emphasis on the behavior of three energy regions, slow, intermediate and fast neutrons within the core at different temperatures. The slow neutron flux which has the characteristic of a Maxwell- Boltzmann distribution were found to shift to larger values of neutron flux at higher energies as the fuel temperature increased, while fast neutron flux spectra remained relatively constant. In addition, the results of the fit of the slow neutron flux with a modified Maxwell-Boltzmann equation confirmed that in the presence of the neutron source, leakage and absorption, the effective neutron temperatures is above the medium temperatures. From these results, it was clear that the detection system will need to monitor both slow and fast neutron flux. Placing neutron detectors inside the reactor core, that are sensitive to a particular energy range of slow and fast neutrons, would thus provide information about the change of temperature in the fuel and hence act as an in-core temperature monitor. A detection mechanism was developed that employs the neutron-induced break-up reaction of 6Li and 12C into α-particles. These materials make excellent neutron converters without interference due to γ-rays, as the contributions from 6Li(γ,np)4He and 12C(γ,3α) reactions are negligible. The mass spectrometer measures the 4He partial pressure as a function of time under high vacuum with the help of pressure gradient provided by a high-vacuum turbomolecular pump and a positive-displacement fore-vacuum pump connected in series. A cryogenic trap, which contains a molecular sieve made of pellets 1.6 mm in diameter, was also designed and manufactured to remove impurities which cause a background in the lighter mass region of the spectrum. The development and testing of the high flux neutron detection system were performed at the iThemba Laboratory for Accelerator Based Sciences (LABS), South Africa. These tests were carried out with a high energy proton beam at the D-line neutron facility, and with a fast neutron beam at the neutron radiation therapy facility. To test the principle and capability of the detection system in measuring high fluxes, a high intensity 66 MeV proton beam was used to produce a large yield of α-particles. This was done because the proton inelastic scattering cross-section with 12C nuclei is similar to that of neutrons, with a threshold energy of about 8 MeV for both reactions. Secondly, the secondary fast neutrons produced from the 9Be(p,n)9B reaction were also measured with the fast neutron detector. The response of this detection system during irradiation was found to be relatively fast, with a rise time of a few seconds. This is seen as a sharp increase in the partial pressure of 4He gas as the proton or neutron beam bombards the 12C material. It was found that the production of 4He with the proton beam was directly proportional to the beam intensity. The number of 4He atoms produced per second was deduced from the partial pressure observed during the irradiation period. With a neutron beam of 1010 s−1 irradiating the detector, the deduced number of 4He atoms was 109 s−1. When irradiation stops, the partial pressure drops exponentially. This response is attributed to a small quantity of 4He trapped in the present design. Overall, the measurements of 4He partial pressure produced during the tests with proton and fast neutron beams were successful and demonstrated proof of principle of the new detection technique. It was also found that this system has no upper neutron flux detection limit; it can be even higher than 1014 n·cm−2·s−1. The lifetime of this detection system in nuclear reactor environment is practically unlimited, as determined by the known ability of stainless steel to keeps its integrity under the high radiation levels. Hence, it is concluded that this high flux neutron detection system is excellent for neutron detection in the presence of high γ-radiation level and provides real-time flux measurements.