Browsing by Author "Ruiters, Ashley"
Now showing 1 - 3 of 3
Results Per Page
Sort Options
- ItemExtract from used Xpert MTB/ RIF Ultra cartridges is useful for accurate second-line drug-resistant tuberculosis diagnosis with minimal rpoB-amplicon cross-contamination risk(Nature Research (part of Springer Nature), 2020) Venter, Rouxjeane; Minnies, Stephanie; Derendinger, Brigitta; Tshivhula, Happy; De Vos, Margaretha; Dolby, Tania; Ruiters, Ashley; Warren, Robin M.; Theron, GrantXpert MTB/RIF Ultra (Ultra) detects Mycobacterium tuberculosis and rifampicin resistance. Follow-on drug susceptibility testing (DST) requires additional sputum. Extract from the diamond-shaped chamber of the cartridge (dCE) of Ultra’s predecessor, Xpert MTB/RIF (Xpert), is useful for MTBDRsl-based DST but this is unexplored with Ultra. Furthermore, whether CE from non-diamond compartments is useful, the performance of FluoroType MTBDR (FT) on CE, and rpoB cross-contamination risk associated with the extraction procedure are unknown. We tested MTBDRsl, MTBDRplus, and FT on CEs from chambers from cartridges (Ultra, Xpert) tested on bacilli dilution series. MTBDRsl on Ultra dCE on TB-positive sputa (n = 40) was also evaluated and, separately, rpoB amplicon cross-contamination risk . MTBDRsl on Ultra dCE from dilutions ≥103 CFU/ml (CTmin <25, >“low semi-quantitation”) detected fluoroquinolone (FQ) and second-line injectable (SLID) susceptibility and resistance correctly (some SLIDs-indeterminate). At the same threshold (at which ~85% of Ultra-positives in our setting would be eligible), 35/35 (100%) FQ and 34/35 (97%) SLID results from Ultra dCE were concordant with sputa results. Tests on other chambers were unfeasible. No tubes open during 20 batched extractions had FT-detected rpoB cross-contamination. False-positive Ultra rpoB results was observed when dCE dilutions ≤10−3 were re-tested. MTBDRsl on Ultra dCE is concordant with isolate results. rpoB amplicon cross-contamination is unlikely. These data mitigate additional specimen collection for second-line DST and cross-contamination concerns.
- ItemMycobacterial genomic DNA from used Xpert MTB/RIF cartridges can be utilised for accurate second-line genotypic drug susceptibility testing and spoligotyping(Nature, 2017) Venter, Rouxjeane; Derendinger, Brigitta; De Vos, Margaretha; Pillay, Samantha; Dolby, Tanya; Simpson, John; Kitchin, Natasha; Ruiters, Ashley; Van Helden, Paul D.; Warren, Robin M.; Theron, GrantXpert MTB/RIF (Xpert) is a widely-used test for tuberculosis (TB) and rifampicin-resistance. Second-line drug susceptibility testing (DST), which is recommended by policymakers, typically requires additional specimen collection that delays effective treatment initiation. We examined whether cartridge extract (CE) from used Xpert TB-positive cartridges was, without downstream DNA extraction or purification, suitable for both genotypic DST (MTBDRplus, MTBDRsl), which may permit patients to rapidly receive a XDR-TB diagnosis from a single specimen, and spoligotyping, which could facilitate routine genotyping. To determine the limit-of-detection and diagnostic accuracy, CEs from dilution series of drug-susceptible and -resistant bacilli were tested (MTBDRplus, MTBDRsl). Xpert TB-positive patient sputa CEs (n = 85) were tested (56 Xpert-rifampicin-susceptible, MTBDRplus and MTBDRsl; 29 Xpert-rifampicin-resistant, MTBDRsl). Spoligotyping was done on CEs from dilution series and patient sputa (n = 10). MTBDRplus had high non-valid result rates. MTBDRsl on CEs from dilutions ≥103CFU/ml (CT ≤ 24, >“low” Xpert semiquantitation category) was accurate, had low indeterminate rates and, on CE from sputa, highly concordant with MTBDRsl isolate results. CE spoligotyping results from dilutions ≥103CFU/ml and sputa were correct. MTBDRsl and spoligotyping on CE are thus highly feasible. These findings reduce the need for additional specimen collection and culture, for which capacity is limited in high-burden countries, and have implications for diagnostic laboratories and TB molecular epidemiology.
- ItemMycobacterial genomic DNA from used Xpert MTB/RIF cartridges can be utilised for accurate secondline genotypic drug susceptibility testing and spoligotyping(Springer Nature, 2017-11-01) Venter, Rouxjeane; Derendinger, Brigitta; De Vos, Margaretha; Pillay, Samantha; Dolby, Tanya; Simpson, John; Kitchin, Natasha; Ruiters, Ashley; Van Helden, Paul D.; Warren, Robin M.; Theron, GrantENGLISH ABSTRACT: Xpert MTB/RIF (Xpert) is a widely-used test for tuberculosis (TB) and rifampicin-resistance. Second-line drug susceptibility testing (DST), which is recommended by policymakers, typically requires additional specimen collection that delays effective treatment initiation. We examined whether cartridge extract (CE) from used Xpert TB-positive cartridges was, without downstream DNA extraction or purification, suitable for both genotypic DST (MTBDRplus, MTBDRsl), which may permit patients to rapidly receive a XDR-TB diagnosis from a single specimen, and spoligotyping, which could facilitate routine genotyping. To determine the limit-of-detection and diagnostic accuracy, CEs from dilution series of drug-susceptible and -resistant bacilli were tested (MTBDRplus, MTBDRsl). Xpert TB-positive patient sputa CEs (n = 85) were tested (56 Xpert-rifampicin-susceptible, MTBDRplus and MTBDRsl; 29 Xpert-rifampicin-resistant, MTBDRsl). Spoligotyping was done on CEs from dilution series and patient sputa (n = 10). MTBDRplus had high non-valid result rates. MTBDRsl on CEs from dilutions ≥103CFU/ml (CT ≤ 24, >“low” Xpert semiquantitation category) was accurate, had low indeterminate rates and, on CE from sputa, highly concordant with MTBDRsl isolate results. CE spoligotyping results from dilutions ≥103CFU/ml and sputa were correct. MTBDRsl and spoligotyping on CE are thus highly feasible. These findings reduce the need for additional specimen collection and culture, for which capacity is limited in high-burden countries, and have implications for diagnostic laboratories and TB molecular epidemiology.