Flux flow and cleaning enhancement in a spiral membrane element, using continuous infrasonic backpulsing

Date
2010
Authors
McLachlan D.S.
Koen D.
Sanderson R.D.
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
The effect of backpulsing, into the permeate space of a 2.5 inch spiral wrap membrane, on the prevention of fouling (flux enhancement) was investigated experimentally. These experiments were performed using a 500 mg·l-1 dextrin solution and a 100 000 MCWO polypropylene membrane, with a feed pressure of 100 kPa and a cross-flow rate of 1000 l·h-1. Experimental results showed that a backpulse with a duration of about 170 ms, a repeat requency of 1 s and differential peak pulse pressure, measured at the outlet of the permeate space, of 38 kPa gave the best results for the parameters used in the current experiments. In this case the saturation flux with backpulsing was 82% of the clean water value and 3.9 times the saturation flux obtained with no backpulsing.
Description
Keywords
Back pulsing, Clean waters, Cross flows, Feed pressure, Flux enhancement, Flux flow, Infrasonic, Membrane cleaning, Peak pulse, Polypropylene membrane, Saturation flux, Spiral membrane element, Spiral wrap element, Cleaning, Experiments, Membranes, flux measurement, fouling, infrasonics, membrane
Citation
Water SA
36
4