Comparison of the accuracy of the calibration model on the double and single integrating sphere systems

dc.contributor.authorSingh A.
dc.contributor.authorKarsten A.
dc.date.accessioned2011-10-13T16:58:30Z
dc.date.available2011-10-13T16:58:30Z
dc.date.issued2011
dc.description.abstractThe accuracy of the calibration model for the single and double integrating sphere systems are compared for a white light system. A calibration model is created from a matrix of samples with known absorption and reduced scattering coefficients. In this instance the samples are made using different concentrations of intralipid and black ink. The total and diffuse transmittance and reflectance is measured on both setups and the accuracy of each model compared by evaluating the prediction errors of the calibration model for the different systems. Current results indicate that the single integrating sphere setup is more accurate than the double system method. This is based on the low prediction errors of the model for the single sphere system for a He-Ne laser as well as a white light source. The model still needs to be refined for more absorption factors. Tests on the prediction accuracies were then determined by extracting the optical properties of solid resin based phantoms for each system. When these properties of the phantoms were used as input to the modeling software excellent agreement between measured and simulated data was found for the single sphere systems. © 2011 SPIE.
dc.description.versionConference Paper
dc.identifier.citationProceedings of SPIE - The International Society for Optical Engineering
dc.identifier.citation8192
dc.identifier.citationhttp://www.scopus.com/inward/record.url?eid=2-s2.0-80052446952&partnerID=40&md5=e105cba79a56cb44827659681f5b9637
dc.identifier.issn0277786X
dc.identifier.other10.1117/12.899879
dc.identifier.urihttp://hdl.handle.net/10019.1/16747
dc.subjectCalibration model
dc.subjectIntegrating sphere
dc.subjectLight tissue interaction
dc.subjectAbsorption factor
dc.subjectCalibration model
dc.subjectDouble system
dc.subjectHe-Ne lasers
dc.subjectIntegrating sphere
dc.subjectIntegrating spheres
dc.subjectIntralipids
dc.subjectLight tissue interaction
dc.subjectmatrix
dc.subjectModeling softwares
dc.subjectPrediction accuracy
dc.subjectPrediction errors
dc.subjectReduced scattering coefficients
dc.subjectSimulated data
dc.subjectSphere systems
dc.subjectWhite light sources
dc.subjectWhite light systems
dc.subjectAbsorption
dc.subjectCalibration
dc.subjectErrors
dc.subjectForecasting
dc.subjectLight sources
dc.subjectMedical applications
dc.subjectMedical imaging
dc.subjectOptical properties
dc.subjectTissue
dc.subjectSpheres
dc.titleComparison of the accuracy of the calibration model on the double and single integrating sphere systems