Radiation to transmission lines with varying load and ground conditions

Stuart T.E.W. ; Reader H.C. ; van der Merwe J. (1999)

Conference Paper

A transmission line above both an ideal and a lossy ground is illuminated by a plane wave, while its terminations are varied. An intention of this study, for EMI purposes, is to explore the minimisation of power induced in the loads, both by simulation and measurement. The simulations are performed in the time domain and the frequency domain, while measurements are made in the frequency domain with a network analyser. Great care is needed for the measurement procedures.

Please refer to this item in SUNScholar by using the following persistent URL: http://hdl.handle.net/10019.1/8741