ITEM VIEW

Cross-coupling inductance parameter estimation for more accurate performance evaluation of wound-field flux modulation machines

dc.contributor.authorMabhula, Mkhululien_ZA
dc.contributor.authorAkuru, Udochukwu B.en_ZA
dc.contributor.authorKamper, Maarten J.en_ZA
dc.date.accessioned2020-11-30T12:25:38Z
dc.date.available2020-11-30T12:25:38Z
dc.date.issued2020-10-22
dc.identifier.citationMabhula, M., Akuru, U. B. & Kamper, M. J. 2020. Cross-coupling inductance parameter estimation for more accurate performance evaluation of wound-field flux modulation machines. Electronics, 9(11):1748, doi:10.3390/electronics9111748
dc.identifier.issn2079-9292 (online)
dc.identifier.otherdoi:10.3390/electronics9111748
dc.identifier.urihttp://hdl.handle.net/10019.1/108949
dc.descriptionCITATION: Mabhula, M., Akuru, U. B. & Kamper, M. J. 2020. Cross-coupling inductance parameter estimation for more accurate performance evaluation of wound-field flux modulation machines. Electronics, 9(11):1748, doi:10.3390/electronics9111748.
dc.descriptionThe original publication is available at https://www.mdpi.com
dc.descriptionPublication of this article was funded by the Stellenbosch University Open Access Fund
dc.description.abstractENGLISH ABSTRACT: In this paper, a proposed numerical frozen permeability modeling procedure is fully derived to accurately estimate the parameters of two variants of wound-field flux modulation machines (WF-FMMs) namely: wound-field flux switching machine (WF-FSM) and DC-excited vernier reluctance machine (DC-VRM). During the procedure, the contribution of saturation to the variation of the machine parameters is investigated. The parameter variation effects on the machine performance is also investigated. It is shown that analysis of WF-FMMs is better understood by using the proposed procedure which computes accurately the machine parameters.en_ZA
dc.description.urihttps://www.mdpi.com/2079-9292/9/11/1748
dc.format.extent15 pagesen_ZA
dc.language.isoen_ZAen_ZA
dc.publisherMDPIen_ZA
dc.subjectCross-couplingen_ZA
dc.subjectFinite element methoden_ZA
dc.subjectMagnetic fluxen_ZA
dc.subjectElectromagneticsen_ZA
dc.subjectPermanent magnetsen_ZA
dc.titleCross-coupling inductance parameter estimation for more accurate performance evaluation of wound-field flux modulation machinesen_ZA
dc.typeArticleen_ZA
dc.description.versionPublisher's version
dc.rights.holderAuthors retain copyrighten_ZA


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

ITEM VIEW